RE-Y(St)YSWAY-fl TIMF Cable Construction
| CONDUCTOR : | Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request) |
| INSULAION : | PVC compound to EN50290-2-21 Black / White / Red twisted triads with numbered cores |
| BINDER TAPE : | Polyester foil on each twisted triad |
| INDIVIDUAL SCREEN : | Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil |
| BINDER TAPE : | Polyester foil on overall cable core formed by stranded pairs |
| COLLECTIVE SCREEN : | Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil |
| INNER SHEATH : | PVC compound to EN50290-2-22 |
| ARMOUR : | Round galvanised steel wires to EN 10257-1 |
| OUTER SHEATH : | Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request |
RE-Y(St)YSWAY-fl TIMF Cable Application
- Explosion-proof zones (Zone 1/Zone 2) in petroleum, natural gas, chemical, and pharmaceutical plants. Instrumentation connections, intrinsically safe circuits.
- Critical control and measurement systems in power plants (especially nuclear power plants).
- Signaling and control systems for railways and rail transit.
- Monitoring and communication systems in mines and tunnels.
- Any industrial automation application requiring long-distance transmission of analog/digital signals with stringent requirements for electromagnetic interference resistance and mechanical durability.
RE-Y(St)YSWAY-fl TIMF Cable Technical Data
- RATED VOLTAGE :500 V a.c.
- AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
- WORKING TEMPERATURE : -30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)
- MIN BENDING RADIUS (FIXED) :10 x D
RE-Y(St)YSWAY-fl TIMF Cable Standard
- CONSTRUCTION :EN 50288-7
- MATERIAL TYPES & TESTS :EN 50290-2 series
- ELECTRICAL & MECHANICAL TESTS :EN 50289 series
- FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
RE-Y(St)YSWAY-fl TIMF Cable Feature
- Exceptional Safety: Low-smoke, zero-halogen (FL) + flame-retardant (F) construction meets the highest fire safety standards (e.g., EN 45545-2 for rail applications).
- Superior Interference Resistance: Dual-layer shielding (I+M) ensures stable signal transmission in complex electromagnetic environments.
- Robust mechanical properties: Steel wire armoring (St) for demanding installations including dragging, direct burial, and conduit routing.
- Specialized application design: Three-conductor grouping (T) and blue jacket clearly indicate intrinsic safety instrumentation and control circuits for hazardous areas (e.g., chemical plants, oil platforms).
RE-Y(St)YSWAY-fl TIMF Cable Specification
| Cross Sections (mm2) | Nominal Overall Diameter (mm) | Approximate Weight (kg/km) |
|---|---|---|
| 2x3x0,5 | 15.6 | 410 |
| 4x3x0,5 | 17.6 | 530 |
| 8x3x0,5 | 22.8 | 824 |
| 10x3x0,5 | 25.4 | 1080 |
| 12x3x0,5 | 26 | 1160 |
| 16x3x0,5 | 28.3 | 1374 |
| 20x3x0,5 | 31.2 | 1610 |
| 24x3x0,5 | 35.3 | 2092 |
| 2x3x0,75 | 16.7 | 465 |
| 4x3x0,75 | 19 | 613 |
| 5x3x0,75 | 21 | 810 |
| 6x3x0,75 | 22.6 | 910 |
| 8x3x0,75 | 24.8 | 1070 |
| 10x3x0,75 | 27.6 | 1260 |
| 12x3x0,75 | 28.4 | 1374 |
| 16x3x0,75 | 31.2 | 1650 |
| 20x3x0,75 | 35.5 | 2175 |
| 24x3x0,75 | 38.9 | 2506 |
| 2x3x1 | 17.1 | 488 |
| 4x3x1 | 19.4 | 655 |
| 5x3x1 | 21.7 | 870 |
| 6x3x1 | 23.2 | 968 |
| 8x3x1 | 25.6 | 1155 |
| 10x3x1 | 28.4 | 1360 |
| 12x3x1 | 29.4 | 1500 |
| 16x3x1 | 33 | 1990 |
| 20x3x1 | 36.7 | 2375 |
| 24x3x1 | 40.2 | 2736 |
| 2x3x1,3 | 18.1 | 540 |
| 4x3x1,3 | 21 | 842 |
| 5x3x1,3 | 22.7 | 960 |
| 6x3x1,3 | 24.3 | 1080 |
| 8x3x1,3 | 26.9 | 1295 |
| 10x3x1,3 | 30.1 | 1538 |
| 12x3x1,3 | 31 | 1686 |
| 16x3x1,3 | 35.1 | 2294 |
| 20x3x1,3 | 38.7 | 2698 |
| 24x3x1,3 | 42.5 | 3110 |
| 2x3x1,5 | 18.6 | 568 |
| 4x3x1,5 | 21.9 | 904 |
| 5x3x1,5 | 23.5 | 1020 |
| 6x3x1,5 | 25.4 | 1160 |
| 8x3x1,5 | 27.9 | 1383 |
| 10x3x1,5 | 31.2 | 1640 |
| 12x3x1,5 | 33 | 2004 |
| 16x3x1,5 | 36.7 | 2456 |
| 20x3x1,5 | 40.4 | 2890 |
| 24x3x1,5 | 45.2 | 3645 |
| 2x3x2,5 | 22 | 842 |
| 4x3x2,5 | 25.1 | 1150 |
| 5x3x2,5 | 27 | 1323 |
| 6x3x2,5 | 29.2 | 1502 |
| 8x3x2,5 | 33.2 | 2015 |
| 10x3x2,5 | 37.6 | 2448 |
| 12x3x2,5 | 38.7 | 2695 |
| 16x3x2,5 | 43.4 | 3560 |
| 20x3x2,5 | 48.5 | 4268 |
| 24x3x2,5 | 53.3 | 4948 |
Why Huadong Cable
Our vision is to become an internationally renowned cable brand. Customer satisfaction, employee advancement, and corporate growth are our service tenets. High standards, globalization, and building an international brand are our business philosophy.
About HuaDong
Henan Huadong Cable Co., Ltd., established in 1999, is a state-level high-tech enterprise integrating scientific research, production, and trade. Deeply engaged in the Belt and Road Initiative, Huadong Cable exports its products to over 130 countries worldwide, covering regions including Europe, South America, North America, the Middle East, Africa, Asia, and Oceania.
HuaDong Technology
HuaDong Cable focuses on technological research and development, employing 60 professionals with senior technical titles and holding over 100 invention and utility model patents. The company has assembled a team of experienced technical engineers to ensure the quality of its cable products.
Main Products
Our main products: Marine cables, power cables, overhead cables, fire-resistant cables, low-smoke zero-halogen cables, rubber cables, high-temperature resistant cables, instrumentation and control cables, solar cables, and other products.
ISO, SGS, BV CERTIFICATION; TECHNICAL PATENTS AND PRODUCT CERTIFICATION
TECHNICAL AND CLIENTS
Export Countries
Technical Patents
Annual Productivity
Employees