2XS(F)2Y / N2XS(F)2Y / A2XS(F)2Y / NA2XS(F)2Y are medium-voltage cross-linked polyethylene (XLPE)-insulated, copper-wire-shielded, water-blocking cables (typically rated from 6/10 kV to 18/30 kV). They share a core structure consisting of a three-layer co-extruded XLPE insulation, copper wire braiding plus copper tape overlap shielding, dual-layer longitudinal water blocking, and a PE waterproof sheath.

  • iso-certification
  • ce-certification
  • ccc-certification
  • ul-certification
  • abs-certification

2XS(F)2Y / N2XS(F)2Y / A2XS(F)2Y / NA2XS(F)2Y Construction

Conductors Cu and Al stranded compacted, according to IEC 60228 class 2 and VDE 0295 class 2
Inner semi-conductive layer semi-conductive XLPE compound
Insulation XLPE compound
Outer semi-conductive layer semi-conductive XLPE compound
Water resisting element Layer of semi-conductive water absorbing tapes
Metal screen Cu wires concentrically laid and one contact of Cu tape with thickness of 0.1mm.
Water resisting element -I option - water absorbing insulating tape
-II option - water absorbing powder and a layer of plastic tape
Sheath PE compound

2XS(F)2Y / N2XS(F)2Y / A2XS(F)2Y / NA2XS(F)2Y Application

  • 2XS(F)2Y
  • Main feeder lines in urban distribution networks and feeder lines from substations in industrial zones.
  • N2XS(F)2Y
  • Long-distance overhead-to-underground conversion projects, and suburban or rural power grids.
  • A2XS(F)2Y
  • Direct burial in high-humidity areas; collection lines within wind farms and solar farms in rainy regions.
  • NA2XS(F)2Y
  • Long-distance collection lines for large-scale renewable energy bases (such as large-scale solar farms in Northwest China); landing sections of low-cost submarine cables.

2XS(F)2Y / N2XS(F)2Y / A2XS(F)2Y / NA2XS(F)2Y Standard

  • IEC 60502-2 / DIN VDE 0276-620

2XS(F)2Y / N2XS(F)2Y / A2XS(F)2Y / NA2XS(F)2Y Technical Data

Operating temperature 90°C continuous operation
Overload temperature 130°C /100h per year max./
Short circuit temperature 250°C /5 s max./
Nominal voltage Uo/U: 6/10;12/20 kV
Highest system voltage Uo/U, no more than 6/10; 12/20 kV 12kV; 24kV kV
Test voltage Uo/U 6/10; 12/20 kV
AC (≈) - 5 min 15kV; 30kV kV
DC (=) - 15 min 48kV; 96kV kV

2XS(F)2Y / N2XS(F)2Y / A2XS(F)2Y / NA2XS(F)2Y Feature

  • Insulation System: Utilizes a three-layer co-extrusion process (inner semiconductive layer + XLPE main insulation + outer semiconductive layer), dry cross-linking, low partial discharge level (≤5 pC), high electrical strength, and a design life of ≥30 years.
  • Metal Shielding Structure: Copper wires are concentrically wound to form the primary shield, with an additional layer of 0.1 mm thick copper tape overlapping and covering the shield. The copper wires carry steady-state induced currents and short-circuit fault currents, while the copper tape serves the dual purpose of securing the copper wires and providing auxiliary short-circuit capacity.
  • Longitudinal Water-Barrier Design: Features a dual-layer water-barrier system. The first layer consists of a wrapped semiconductive water-barrier tape; the second layer can be either a water-barrier insulating tape (Type I) or a combination of water-barrier powder and plastic tape (Type II). Upon contact with water, the water-barrier material expands to seal gaps, preventing moisture migration along the cable’s longitudinal axis.
  • Outer Sheath Material: A PE (polyethylene) sheath is used, which has an extremely low water vapor permeability (approximately 1/10 that of PVC), is resistant to low temperatures (-40°C), and is resistant to chemical corrosion from acids and alkalis, making it suitable for humid and underground environments.
  • Fire Safety Limitations: The PE sheath is not flame-retardant; it will continue to burn and produce dripping when exposed to fire. Direct use is strictly prohibited in locations with fire safety requirements, such as indoor substations and underground passageways with high pedestrian traffic.

2XS(F)2Y / N2XS(F)2Y / A2XS(F)2Y / NA2XS(F)2Y Specification

Number of con­ductors and nominal cross sectionThic­kness of insulationThic­kness of sheathNominal cross sec­tion of screenCable diameter approx.2XS(F)2Y,N2XS(F)2YA2XS(F)2Y, NA2XS(F)2Y
minmaxMass of Cu approx.Mass of cable approx.Mass of Al approx.Mass of Cu approx.Mass of cable approx.
Nxmm2mmmmmm2mmmmkg/kmkg/kmkg/kmkg/kmkg/km
6/10 kV
1x35rm/163,42,516232849390694176683
1x50rm/163,42,51624296041043127176745
1x70rm/163,42,51626317931279183176846
1x95rm/163,42,516273210331564254176961
1x120rm/163,42,5162934125518223211761064
1x150rm/163,42,516*3035150721163941761180
1x185rm/163,42,516*3237184224954951761325
1x240rm/163,42,516*3439236530816491761542
1x150rm/253,42,5253035159622003942651264
1x185rm/253,42,5253237193025794952651409
1x240rm/253,42,5253439245431656492651626
1x300rm/253,42,5253641298037528122651849
1x400rm/353,42,53540453836468310433632254
1x500rm/353,42,53543484807573813743632599
12/20 kV
1x35rm/165,52,5162732493108194176858
1x50rm/165,52,51628336041228127176927
1x70rm/165,52,516303579314731831761039
1x95rm/165,52,5163136103317682541761165
1x120rm/165,52,5163338125519523211761194
1x150rm/165,52,516*3439150723403941761403
1x185rm/165,52,516*3641184227304951761560
1x240rm/165,52,516*3944236534166491761876
1x150rm/255,52,5253439159624243942651487
1x185rm/255,52,5253641193028144952651644
1x240rm/255,52,5253944245434166492651876
1x300rm/255,52,5254146298040188122652114
1x400rm/355,52,53544493836496610433632537
1x500rm/355,52,53547524807607313743632919
18/30 kV
1x50rm/1682,516333860414651271761164
1x70rm/1682,516354079317221831761289
1x95rm/1682,5163641103320302541761427
1x120rm/1682,5163843125523083211761550
1x150rm/2582,5253944159627073942651770
1x185rm/2582,5254146193031094952651939
1x240rm/2582,5254348245437286492652189
1x300rm/2582,5254651298043618122652458
1x400rm/3582,53549543836534710433632918
1x500rm/3582,53552574807648213743633343

Why Huadong Cable

Our vision is to become an internationally renowned cable brand. Customer satisfaction, employee advancement, and corporate growth are our service tenets. High standards, globalization, and building an international brand are our business philosophy.

About HuaDong

Henan Huadong Cable Co., Ltd., established in 1999, is a state-level high-tech enterprise integrating scientific research, production, and trade. Deeply engaged in the Belt and Road Initiative, Huadong Cable exports its products to over 130 countries worldwide, covering regions including Europe, South America, North America, the Middle East, Africa, Asia, and Oceania.

HuaDong Technology

HuaDong Cable focuses on technological research and development, employing 60 professionals with senior technical titles and holding over 100 invention and utility model patents. The company has assembled a team of experienced technical engineers to ensure the quality of its cable products.

Main Products

Our main products: Marine cables, power cables, overhead cables, fire-resistant cables, low-smoke zero-halogen cables, rubber cables, high-temperature resistant cables, instrumentation and control cables, solar cables, and other products.

ISO, SGS, BV CERTIFICATION; TECHNICAL PATENTS AND PRODUCT CERTIFICATION

Certification-item-01 Certification-item-02 Certification-item-03 Certification-item-04 Certification-item-05 Certification-item-06 Certification-item-07 Certification-item-08

TECHNICAL AND CLIENTS

130+

Export Countries

100+

Technical Patents

3 billion+

Annual Productivity

400+

Employees

Clients-item-01 Clients-item-02 Clients-item-03 Clients-item-04 Clients-item-05 Clients-item-06 Clients-item-07 Clients-item-08

Please feel free to contact us if you have any questions.

TECHNICAL & SALES SUPPORT

If you have any questions, please contact us. We’ll do our best to help.

    x